Blown Battery Fuse Troubleshooting

Use this procedure to help troubleshoot a failed "blown" battery fuse.

Main battery fuse failure

An indication that the battery fuse has failed is that the machine will operate as normal except that the incline lift function does not operate,

  1. Remove the main battery fuse from the inline fuse inline holder and verify condition. Use an ohm meter to verify that there is continuity (zero ohms) between the two fuse connection pins.
    1. If the fuse is good, replace the removed fuse.
    2. If the fuse is bad, replace the fuse.
  2. Make sure the battery is charged and properly connected, see Battery Replacement.
  3. Make sure that the battery positive and negative cables are installed correctly and securely connected at both ends of the battery power cable.
  4. Switch the power ON. Verify that the machine power has been restored. Wait for a few minutes and make sure the fuse does not fail again.
    1. If the fuse fails after power up, the fuse is not causing the power failure, continue troubleshooting the cause of the electrical power failure.

 

 

 

See Also

System Troubleshooting Procedures

 

 

 

 

Contact Precor Customer Support (Ph 800.786.8404) with any questions.